GCK7799P

Handling/Precautions

Follow precautions normally taken for handling lube oil stocks.

This product is temperature sensitive.

Do not heat over the maximum loading/unloading temperature to avoid possible release of extremely odorous alkyl marcaptans and / or toxic hydrogen sulfide.

Localized high temperatures should be avoided during.

Electrical steam or hot oil heating systems with a self-limiting maximum temperature not exceeding 120  ̊C /250  ̊F (e.g.low pressure steam at 2 bar (g) or 30 psig) are recommended.

Min load/unload temp: 55c (131 F)

Min load/unload temp: 55c (131 F)

Min load/unload temp: 55c (131 F)

Vis @ min load/unload temp: 650 cSt

Vis @ min load/unload temp: 650 cSf

Maximum storage temperature:

Do not reheat above

Performance (Additive Treat (rate %wt) )Mono & MultiGCK 7799P
API SMMono & Multi8%
API SNMono & Multi9%
Typical InspectionsResult
Min-Max
Test Methods
Kinematic Viscosity (100  ̊C), cSt80 – 100ASTM D-445
Flash Point, PM cup, ̊CMin 130ASTM D-93
Sulphur Content, %wt0.75 – 1.35ASTM D-4951
Calcium Content, %wt1.8 – 2.6ASTM D-4927
Zinc Content, %wt0.9 – 1.9ASTM D-4951
Nitro Content N%0.7 – 1.7ASTM D-874
Molybdenum ppm450 – 750ASTM D-6595
Boron ppm1800 – 2500ASTM D-4052
Total Base Number, mg KOH/g80 – 106ASTM D-6595